UK lighting wiring diagrams

The common ways to wire domestic lighting in the UK — one, two and three switches (intermediate), and how the same switching controls one, two or three lights. Diagrams show the switch-drop / loop-in-at-ceiling method used in most UK installations to BS 7671.

Reference only

These diagrams are simplified for teaching. Actual installations must be designed and installed by a competent person to BS 7671:2018+A4:2026. Switch-drops using twin-and-earth cable require a brown line, a brown switched-line (blue sleeved brown) and an earth — with the neutral looped at the ceiling rose.

Legend

  • Brown — Line (permanent L)
  • Blue — Neutral (N)
  • Switched line (blue sleeved brown in T&E)
  • Green/Yellow — CPC (earth)
  • Strapper (between switches)
  • Grey sheath — T&E cable (2C+E)

In the topology diagrams below, earth (CPC) is present at every point but drawn only where it clarifies the wiring. In the T&E diagrams further down, the CPC is drawn explicitly.

One light, one switch — one-way switching

The simplest arrangement. Line goes to the switch, switched line goes to the lamp, neutral goes directly to the lamp. This is what a hallway or WC light typically uses.

One-way switch → one lamp

Line to switch COM; switched-line back to lamp; neutral straight to lamp.

LSwitch S1L1N

One light, two switches — two-way switching

Two switches control the same lamp — either can turn it on or off. Standard for stairs (top and bottom of stairs) and long hallways with a door at each end. Uses 3-core-and-earth "strappers" between the switches.

Two-way switching (2 switches, 1 lamp)

Line to COM of S1; L1/L2 of S1 to L1/L2 of S2 (strappers); COM of S2 back to lamp; neutral straight to lamp.

LC12Switch S1C12Switch S2L1N

One light, three (or more) switches — intermediate switching

Every switch beyond the second is an intermediate switch, wired between the two two-way end switches. It crosses over the two strappers. You can add as many intermediate switches as you like in the middle of the run — common on long landings or open-plan spaces with three or four entrances.

Intermediate switching (3 switches, 1 lamp)

Two-way at each end, intermediate switch in the middle crosses the strappers.

LC12S1 (2-way)S2 (intermediate)C12S3 (2-way)L1N

Two lamps, one switch

Two lamps wired in parallel from the same switched line — e.g. two pendants over a dining table, or two downlighters over a kitchen island. Lamps are always wired in parallel in domestic lighting; never in series (series would leave both dim and both fail if either goes).

One switch → two lamps in parallel

Switched line feeds both lamps; both share the neutral.

LSwitch S1L1L2N

Three lamps, one switch

Same principle — three lamps in parallel on a single switch. Typical for a set of three downlighters over a worktop, or three pendants over a breakfast bar.

One switch → three lamps in parallel

Switched line loops from lamp to lamp; each lamp also connects to the neutral.

LSwitch S1L1L2L3N

Two lamps, two-way switching

Combine the two ideas: two switches controlling two lamps together. Both lamps come on and off from either switch. Add an intermediate in the middle for a third switch.

Two-way switching → two lamps

Standard 2-way pair, then the COM of S2 feeds both lamps in parallel.

LC12S1C12S2L1L2N

Cable level

The same circuits in real twin-and-earth (T&E) cable

The diagrams above show topology. In practice UK lighting is wired in twin-and-earth (brown / blue / bare CPC) plus, where two-way or intermediate switching is used, 3-core-and-earth(brown / black / grey / bare CPC) between the switches. The lampholder is fed from a 3-plate loop-in ceiling rose — three separate terminal blocks: Loop (permanent line), Neutral, and Switched line, with a dedicated earth (CPC) bar.

The blue conductor of a T&E switch drop is always sleeved brown at both ends because it is a switched line, not a neutral (Regulation 514.4). In the diagrams below it is shown dashed amber for clarity.

A. One-way switching — 3-plate loop-in rose

Feed from the consumer unit lands on the Loop, Neutral and earth terminals of the rose. A single T&E drops down to the switch: brown = permanent line to COM; blue (sleeved brown) = switched line back up to the SwL block. The lampholder is fed from SwL (line) and N.

One-way switching in T&E (single lamp)

Feed at ceiling; one T&E drop to a one-way switch.

CONSUMERUNIT 6AT&E 1.5mm² · L / N / CPCLOOPNSwLCPC (earth) bar3-plate ceiling roseL1T&E switch dropCOML11-way switchFeed from 6A MCB/RCBOBrown → COMBlue(brown) → L1

B. Two lamps looped rose-to-rose (still one switch)

The permanent line, neutral and switched line are looped from the first rose to the second in a further T&E — but this one is a 3-core loop (perm L on LOOP-to-LOOP, N-to-N, SwL-to-SwL, CPC). Since a standard T&E only has two conductors, the loop between roses is normally run in 3-core-and-earth so all three functions travel together.

Loop-in: two lamps, one switch

Feed → rose 1 → 3C+E loop → rose 2. Switch drop from rose 1 only.

CU 6AFeed T&ELOOPNSwLCPC (earth) barRose 13C+E loop (L / N / SwL + CPC)LOOPNSwLCPC (earth) barRose 2L1L2T&E dropCOML11-way switch

C. Two-way switching — feed at rose, 3C+E strappers

The switch drop is one T&E from the rose to S1 (brown = perm line to S1 COM, blue-sleeved-brown = SwL return to the rose SwL block). Between S1 and S2 is 3-core-and-earth: brown and black are the two strappers landed on L1 and L2, grey (sleeved brown) carries the SwL from S2's COM back through the S1 back-box and up the T&E's blue core to the rose. Either switch turns the lamp on or off.

Two-way switching in T&E + 3C+E

One T&E drop to S1 (perm L down, SwL up). 3C+E between S1 and S2.

CU 6AFeed T&ELOOPNSwLCPC (earth) bar3-plate roseL1T&E dropL1COML2S1 (2-way)3C+E: brown/black = L1/L2 straps · grey = SwL return · CPCL1COML2S2 (2-way)

D. Intermediate switching — 3 switches in T&E / 3C+E

Same T&E switch drop from the rose to S1. Between S1 and S2, and again between S2 and S3, is 3-core-and-earth. The intermediate switch (S2) has four terminals and swaps the two strappers when it operates; the grey conductor (sleeved brown) again carries the SwL return from S3's COM back to the rose. Any number of intermediate switches can be added by repeating S2.

Intermediate switching in T&E + 3C+E

Rose → S1 (T&E drop) → S2 (intermediate, 3C+E each side) → S3.

CU 6AFeed T&ELOOPNSwLCPC (earth) bar3-plate roseL1T&E dropL1COML2S1 (2-way)3C+E1234S2 (intermediate)3C+EL1COML2S3 (2-way)

Inside an intermediate switch

An intermediate switch is a 4-terminal, double-pole crossover. It has no COM. The four terminals are usually marked L1 / L2 (top) and L3 / L4 (bottom), or simply 1 · 2 · 3 · 4. Internally it does one of two things depending on switch position:

  • Position A (straight-through): 1↔3 and 2↔4 — the two strappers pass through unchanged.
  • Position B (crossed): 1↔4 and 2↔3 — the strappers swap over.

That crossover is the whole trick: flipping any intermediate reverses which strapper is "live", which flips the state of the lamp regardless of where S1 and S3 are set. You can chain as many intermediates as you like between the two end two-way switches.

Terminal-by-terminal in T&E / 3C+E

Using the diagram above (Rose → S1 → S2 intermediate → S3), with strappers sleeved brown at both ends:

  • 3C+E from S1 → S2 (left side):
    • Brown (S1 L1) → S2 terminal 1 (top-left).
    • Black sleeved brown (S1 L2) → S2 terminal 2 (top-right).
    • Grey sleeved brown (S1 COM = permanent live from the switch drop) is not used at S2 — cap it off in the back-box, or better, don't bring it through: the permanent live only needs to reach S1's COM.
    • CPC → earth terminal in the S2 back-box (and to the metal plate if used).
  • 3C+E from S2 → S3 (right side):
    • Brown → S2 terminal 3 (bottom-left) and S3 L1.
    • Black sleeved brown → S2 terminal 4 (bottom-right) and S3 L2.
    • Grey sleeved brown → S3 COM. This is the switched-live return that goes all the way back through S1's drop, up the T&E to the rose's SwL terminal, and feeds the lampholder.
    • CPC → earth terminal at both ends.
  • Result at S2: only terminals 1–2–3–4 are used. Position A holds 1-3 / 2-4 straight; position B swaps to 1-4 / 2-3. Nothing else is wired to the intermediate — no permanent live, no neutral, only the two pairs of strappers and the CPC.

Truth table — S1 / S2 (intermediate) / S3

Any single switch flip changes the lamp state. With three switches there are 8 combinations — 4 ON and 4 OFF.

S1S2 (int.)S3Lamp
L1StraightL1ON
L1StraightL2OFF
L1CrossedL1OFF
L1CrossedL2ON
L2StraightL1OFF
L2StraightL2ON
L2CrossedL1ON
L2CrossedL2OFF

Reading a 3-plate ceiling rose in real life

  • Loop terminal — all the permanent (unswitched) brown lines land here. This is where the perm-L feeds out to switch drops or to the next rose. Nothing on the lampholder connects to this block.
  • Neutral terminal — all blue neutrals land here, including the lampholder neutral flex.
  • Switched-live terminal — the sleeved-brown return from the switch(es) lands here and also feeds the lampholder line flex.
  • Earth bar — every CPC (bare copper, sleeved green/yellow) from every cable lands on the rose earth terminal, including a CPC to any metal lampshade or backplate (411.3.1.1).
  • • A modern rose has slots for two or three cables — an incoming feed T&E, an outgoing 3C+E loop to the next rose, and a T&E switch drop.

Notes for anyone wiring this in practice

  • • Use blue-sleeved brown (blue oversleeved with brown) or brown-oversleeved-blue where an old cable colour represents a switched line — mark it clearly at both ends. Modern cable: brown = line, blue = switched line (sleeved brown), green/yellow = CPC.
  • • Two-way switch drops need 3-core-and-earth (brown, black, grey + CPC) between switches. Blackand grey are re-purposed as strappers and should be sleeved brown at both ends.
  • • Every switch back-box and every ceiling rose must have a CPC terminated at an earth terminal — including metal switch plates (Regulation 411.3.1.1).
  • • Domestic lighting circuits in the UK are typically 6A radials from a 6A MCB/RCBO in the consumer unit; some installers use 10A. Number of points is limited by the circuit design, not a fixed maximum.
  • • All lighting circuits in a domestic property require RCD protection (30 mA) — normally an RCBO on the lighting circuit at the consumer unit.